9.Finotello, A., Gorla, R., Brambilla, N., Bedogni, F., Auricchio, F., and Morganti, S. Finite element analysis of transcatheter aortic valve implantation: Insights on the modelling of self-expandable devices. J. Mech. Behav. Biomed. Mater. 2021. 123:104772. https://doi.org/10.1016/j.jmbbm.2021.104772.
10.Cataloglu, A., Clark, R. E., and Gould, P. L. Stress analysis of aortic valve leaflets with smoothed geometrical data. J. Biomech. 1977. 10(3):153–158. https://doi.org/10.1016/0021-9290(77)90053-7.
11.Martin, C., and Sun, W. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: a fatigue simulation study. J. Biomech. 2015. 48(12): 3026–3034. https://doi.org/10.1016/j.jbiomech.2015.07.031.
12.Xuan, Y., Krishnan, K., Ye, J., Dvir, D., M. Guccione, J., GE, L., et al. Stent and leaflet stresses in 29-mm second-generation balloon expandable transcatheter aortic valve. Ann. Thorac. Surg. 2017. 104(3): 773–781. https://doi.org/10.1016/j.athoracsur.2017.01.064.
13.Li, K., and Sun, W. Simulated transcatheter aortic valve deformation: A parametric study on the impact of leaflet geometry on valve peak stress. Inter. J. Num. Method. Biomed. Eng. 2017. 33(3): e02814. https://doi.org/10.1002/cnm.2814.
16.Carbonaro, D., Gallo, D., Morbiducci, U., Audenino, A., and Chiastra, C. In silico biomechanical design of the metal frame of transcatheter aortic valves: multiobjective shape and cross-sectional size optimization. Struct. Multidiscip. Optim. 2021. 64: 1825–1842. https://doi.org/10.1007/s00158-021-02944-w.
17.Morganti, S., Conti, M., Aiello, M., Valentini, A., Reali, A., and Auricchio, F. Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: two clinical cases. J. Biomech. 2014. 47(11): 2547-2555. https://doi.org/10.1016/j.jbiomech.2014.06.007201 4.
18.Wang, Q., Kodali, S., Primiano, C., and Sun, W. Simulations of transcatheter aortic valve implantation: implications for aortic root rupture. Biomech. Model. Mechanobiol. 2015.14(1): 29–38. https://doi.org/10.1007/s10237-014-0583-7.
20.Nematzadeh, F., and Mostaan, H. Numerical investigation of the mechanical performance of thoracic aortic aneursysm (TAA) NiTi stent. Sci. Iranica B. 2020. 5(27):2382-2390. https://doi.org/ 10.24200/sci.2019.51077.1989.
25.Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., and Burriesci, G. Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med. Eng. Phys. 2013. 35(1):125–130. https://doi.org/10.1016/j.medengphy.2012.04.009.
26.Shrivastava, S. Medical device materials. Proceedings from the Materials and Processes for Medical Devices Conferences; 2003 Sep 8-10; Anaheim, California. Asm International; 2004.Available from: https://libcatalog.usc.edu/discovery/fulldisplay.
27.Asgari, S. Anomalous plastic behavior of fine-grained MP35N alloy during room temperature tensile testing. J. Mater. Process. Technol. 2004.155(1):1905–1911. https://doi.org/10.1016/j.jmatprotec.2004.04.280.
28.Bailey J. Implications for leaflet behaviour in heavily calcified patient-specific aortic roots: simulation of transcatheter aortic valve implantation. Thesis, University of Southampton; 2015.
29.Smith, C. R., Leon, M. B., Miller, D. C., Moses, J. W., Svenssen, L. G., and Tuzcu, E. M. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N. Engl. J. Med. 2011. 364(23): 2187–2198. https://doi.org/10.1056/NEJMoa1103510.
31.Martin, C., Pham, T., and Sun, W. Significant differences in the material properties between aged human and porcine aortic tissues. Eur. J. Cardio-Thora. Surg. 2011. 40(1): 28–34. https://doi.org/10.1016/j.ejcts.2010.08.056.
32.ECHONOMY. Tools for Echocardiographic Calculations [Internet]. 2019 [cited 2019 Sep 6]. Available from: http://saric.us/echonomy/CoreValve%20Sizing.htm.
33.Bianchi, M. Numerical Modeling of Transcatheter Aortic Valve Replacement: A Patient-specific Approach to Minimize Clinical Complications. State University of New York at Stony Brook; 2019.
34.Lin, S., Akula, P., and Gu, L. Mechanical performance of bovine pericardial bioprosthetic valves. J. Med. Devices. 2013. 3(7): 030926. https://doi.org/10.1115/1.4024346.